Temperature - NTC
-
Measuring range -20 to +50 °C
-
Accuracy ±0.2 °C (-10 to +50 °C)
-
Resolution 0.1 °C (-20 to +50 °C)
-
Ambient temperature probe
Temperature - TC Type K (NiCr-Ni)
-
Measuring range -200 to +1370 °C
-
Accuracy ±0.4 °C (-100 to +200 °C)
-
±1 °C (-200 to -100.1 °C)
-
±1 °C (200.1 to +1370 °C)
-
Resolution 0.1 °C (-200 to +1370 °C)
Temperature - TC Type S (Pt10Rh-Pt)
-
Measuring range 0 to +1760 °C
-
Accuracy ±1 °C (0 to +1760 °C)
-
Resolution 0.1 °C (0 to +1760 °C)
Differential Pressure - Piezoresistive
-
Measuring range -40 to +40 hPa , -200 to +200 hPa
-
Accuracy ±1.5 % of mv (-40 to -3 hPa)
-
±1.5 % of mv (+3 to +40 hPa)
-
±0.03 hPa (-2.99 to +2.99 hPa)
-
±1.5 % of mv (-200 to -50 hPa)
-
±1.5 % of mv (+50 to +200 hPa)
-
±0.5 hPa (-49.9 to +49.9 hPa)
-
Resolution 0.01 hPa (-40 to +40 hPa) , 0.1 hPa (-200 to +200 hPa)
Absolute Pressure
-
Measuring range 600 to +1150 hPa
-
Accuracy ±10 hPa
-
Resolution 1 hPa
-
opt. when equipped with IR sensor
Flue gas O₂
-
Measuring range 0 to +25 Vol.%
-
Accuracy ±0.8% of fsv (0 to +25 Vol.%)
-
Resolution 0.01 Vol.% (0 to +25 Vol.%)
-
Reaction time t₉₀ 20 s (t95)
Flue gas CO (with H₂-compensation)
-
Measuring range 0 to +10000 ppm
-
Accuracy ±5 % of mv (+200 to +2000 ppm)
-
±10 % of mv (+2001 to +10000 ppm)
-
±10 ppm (0 to +199 ppm)
-
Resolution 1 ppm (0 to +10000 ppm)
-
Reaction time t₉₀ 40 s
-
H₂ only as an indicator
Flue gas COlow
-
Measuring range 0 to 500 ppm
-
Accuracy ±5 % of mv (+40 to +500 ppm)
-
±2 ppm (0 to +39.9 ppm)
-
Resolution 1 ppm (0 to +500 ppm)
-
Reaction time t₉₀ 40 s
-
H₂ only as an indicator
Flue gas NO
-
Measuring range 0 to +4000 ppm
-
Accuracy ±5 % of mv (+100 to +1999 ppm)
-
±10 % of mv (+2000 to +4000 ppm)
-
±5 ppm (0 to +99 ppm)
-
Resolution 1 ppm (0 to +4000 ppm)
-
Reaction time t₉₀ 30 s
Flue Gas Nolow
-
Measuring range 0 to +300 ppm
-
Accuracy ±5 % of mv (+40 to +300 ppm)
-
±2 ppm (0 to +39.9 ppm)
-
Resolution ±0.1 ppm (0 to +300 ppm)
-
Reaction time t₉₀ 30 s
Flue Gas NO2
-
Measuring range 0 to +500 ppm
-
Accuracy ±5 % of mv (+100 to +500 ppm)
-
±5 ppm (0 to +9.99 ppm)
-
Resolution 0.1 ppm (0 to +500 ppm)
-
Reaction time t₉₀ 40 s
Flue Gas SO₂
-
Measuring range 0 to +5000 ppm
-
Accuracy ±5 % of mv (+100 to +2000 ppm)
-
±10 % of mv (+2001 to +5000 ppm)
-
±5 ppm (0 to +99 ppm)
-
Resolution 1 ppm (0 to +5000 ppm)
-
Reaction time t₉₀ 30 s
Flue Gas Degree of Effectivity, Eta (calculated)
-
Measuring range 0 to +120 %
-
Resolution 0.1 % (0 to +120 %)
Flue Gas Loss (calculated)
-
Measuring range 0 to +99.9 %
-
Resolution 0.1 % (0 to +99.9 %)
Flue Gas Dewpoint (calculated)
-
Measuring range 0 to +99.9 °Ctd
-
Resolution 0.1 °Ctd (0 to +99.9 °Ctd)
Flue Gas CO₂ calculation (calculated from O₂)
-
Measuring range 0 to CO₂ max
-
Accuracy calculated from O₂ ±0.2 Vol.%
-
Resolution 0.01 Vol.%
Flue Gas H₂S
-
Measuring range 0 to +300 ppm
-
Accuracy ±5 % of mv (+40 to +300 ppm)
-
±2 ppm (0 to +39.9 ppm)
-
Resolution 0.1 ppm (0 to +300 ppm)
-
Reaction time t₉₀ 35 s
Flue Gas CO₂ - NDIR
-
Measuring range 0 to +50 Vol.%
-
Accuracy ±0.3 Vol.% + 1 % of mv (0 to 25 Vol.%)
-
±0.5 Vol.% + 1.5 % of mv (25 to 50 Vol.%)
-
Resolution 0.01 Vol.% (0 to 25 Vol.%) , 0.1 Vol.% (> 25 Vol.%)
-
Reaction time t₉₀ 10 s
Velocity / Volume flow
-
Measuring range 0 to +40 m/s
-
Resolution 0.1 m/s (0 to +40 m/s)
Methane (CH4)
-
Measuring range 100 to 40000 ppm
-
Accuracy < 400 ppm (100 to 4000 ppm)
-
< 10 % of mv (> 4000 ppm)
-
Resolution 10 ppm
-
Min. O₂ requirement in flue gas 2 % + (2 x mv methane)
-
Reaction time t₉₀ < 40 s
-
Response factor 1
-
Lower explosion limit (LEL) must be adhered to.
-
The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user.
Propane (C₃H₈)
-
Measuring range 100 to 21000 ppm
-
Accuracy < 400 ppm (100 to 4000 ppm)
-
< 10 % of mv (> 4000 ppm)
-
Resolution 10 ppm
-
Min. O₂ requirement in flue gas 2 % + (5 x mV propane)
-
Reaction time t₉₀ < 40 s
-
Response factor 1.5
-
Lower explosion limit (LEL) must be adhered to.
-
The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user.
Butane (C₄H₁₀)
-
Measuring range 100 to 18000 ppm
-
Accuracy < 400 ppm (100 to 4000 ppm)
-
< 10 % of mv (> 4000 ppm)
-
Resolution 10 ppm
-
Min. O₂ requirement in flue gas 2 % + (6.5 x mV butane)
-
Reaction time t₉₀ < 40 s
-
Response factor 2
-
Lower explosion limit (LEL) must be adhered to.
-
The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user.
General Technical Data
-
Housing ABS
-
Protection class IP40
-
Battery type lithium batteries
-
Battery life Maximum load approx. 2.5 h
-
Dimensions 330 x 128 x 438 mm
-
Power supply AC mains unit 100V to 240V (50 to 60 Hz)
-
DC electric tension input 11V to 40V
-
Pump flow 1 l/min. with through-flow monitoring
-
Hose length 16.2 m (corresponds to 5 probe hose extensions)
-
Max. pos. press./flue gas 50 mbar
-
Max. neg. press./flue gas -300 mbar
-
Max. dust load 20 g/m³ dust in flue gas
-
Dewpoint calculation 0 °Ctd; 99 °Ctd
-
Max. humidity load 70 °C dewpoint temperature
-
Trigger input Voltage 5 to 12 Volt (rising or trailing edge) pulse width > 1 sec load: 5 V/max, 5 mA, 12 V/max. 40 mA
-
Maximum 250,000 readings
-
Operating temperature -5 to +45 °C
-
Storage temperature -20 to +50 °C
-
Weight 4800 g