Temperature - Type K TC Technical Data
 
Measuring range -4.0° to 932.0 °F / -20 to +500 °C
Accuracy ± 34 °F (32° to 212 °F) / ± 1 °C (0 to +100 °C)
Resolution 0.1 °F / 0.1 °C
 
 
DC Voltage Technical Data
 
Resolution 600 mV / 0.1 mV
6.000 V / 1 mV
60.00 V / 10 mV
600.0 V / 100 mV
1000 V / 1 V
Accuracy ± (0.8 % of mv + 3 Digit)
 
AC Voltage Technical Data
 
Resolution 600 mV / 0.1 mV
6.000 V / 1 mV
60.00 V / 10 mV
600.0 V / 100 mV
1000 V / 1 V
Accuracy ± (0.8 % of mv + 3 Digit)
 
DC Current Technical Data
 
Resolution 600 μA / 0.1 μA
6000 μA / 1 μA
60.00 mA / 10 μA
600.0 mA / 100 μA
6 A / 1 mA
10 A / 10 mA
Accuracy ± (1.5 % of mv + 5 Digit)
 
AC Current Technical Data
 
Resolution 600 μA / 0.1 μA
6000 μA / 1 μA
60.00 mA / 10 μA
600.0 mA / 100 μA
6 A / 1 mA
10 A / 10 mA
Accuracy ± (1.5 % of mv + 5 Digit)
 
Resistance Technical Data
 
Resolution 60.00 Ohm / 0.01 Ohm
600.0 Ohm / 0.1 Ohm
6.000 kOhm / 1 Ohm
60.00 kOhm / 10 Ohm
600.0 kOhm / 100 Ohm
6.000 MOhm / 1 kOhm
60.00 MOhm / 10 kOhm
Accuracy ± (1.5 % of mv + 3 Digit)
 
Capcitance Technical Data
 
Resolution 6.000 nF / 0.001 nF
60.00 nF / 0.01 nF
600.0 nF / 0.1 nF
6.000 μF / 0.001 μF
60.00 μF / 0.01 μF
600.0 μF / 0.1 μF
6.000 mF / 1 μF
60.00 mF / 10 μF
Accuracy ± (0.5 % of mv + 3 Digit)
 
Frequency Technical Data
 
Resolution 600.0 Hz / 0.1 Hz
6.000 kHz / 1 Hz
60.00 kHz / 10 Hz
600.0 kHz / 100 Hz
6.000 MHz / 1 kHz
60.00 MHz / 10 kHz
Accuracy ± (0.1 % of mv + 1 Digit)
 
General Technical Data
  1. Protection class IP64
  2. Storage temperature 5° to 140 °F / -15 to +60 °C
  3. Weight 12 oz. / 340 g
  4. Overvoltage Category CAT IV 600V; CAT III 1000V
  5. Authorizations TÜV; CSA; CE
  6. Dimensions 7 x 3 x 2 in. / 167 x 85 x 45 mm
  7. Operating temperature 14° to 122 °F / -10 to +50 °C
 
Instrument Measurement Functions
Diode test yes
Continuity Testing yes
Current probe measurement with adapter yes
Display ligthing yes
Hold yes
MinMax yes
Temperature measurement with adapter yes
True RMS yes
Low-pass filter yes
Duty cycle measurement yes
Display (counts) 6,000