Technical Data:
Temperature
-
Measuring range: -50 to +150 °C
-
Accuracy: ±0.5 °C
-
Resolution: 0.1 °C
-
Probe connection: 2 x Plug-in (NTC)
Pressure Measurement
-
Measuring range: -1 to 60 bar
-
Accuracy: ±0.5 % fs
-
Resolution: 0.01 bar
-
Probe connection: 3 x 7/16" – UNF + 1 x 5/8'' – UNF
-
Overload rel. (high pressure): 65 bar
Vacuum Measurement
-
Measuring range: 0 to 20000 micron
-
Accuracy: ± (10 micron + 10 % of mv) (100 to 1000 micron)
-
Resolution:
-
1 micron (0 to 1000 micron)
-
10 micron (1000 to 2000 micron)
-
100 micron (2000 to 5000 micron)
-
500 micron (5000 to 10000 micron)
-
5000 micron (10000 to 20000 micron)
General Technical Data
-
Dimensions: 220 x 125 x 70 mm
-
Operating temperature: -20 to +50 °C
-
Protection class: IP42
-
Battery life: 250 h (without illumination, without Bluetooth®, without vacuum probe)
-
Pressure media: CFC
-
Refrigerants in instrument: 60 profiles:; R11; R12; R123; R1234yf; R1234ze; R125; R13B1; R134a; R14; R142B; R152A; R161; R22; R227; R23; R290; R32; R401A; R401B; R401C; R402A; R402B; R404A; R406A; R407A; R407B; R407C; R407D; R407F; R408A; R409A; R410A; Ra11A; R412A; R413A; R414B; R416A; R417A; R420A; R421A; R421B; R422A; R422B; R422C; R422D; R424A; R426A; R427A; R434A; R437A; R438A; R502; R503; R507; R508A; R508B; R600; R600a; R744 (CO₂); R718 (H₂O); update via App
-
System requirements: requires iOS 7.1 or newer; requires Android 4.3 or newer; requires mobile end device with Bluetooth 4.0
-
Storage temperature: -20 to +60 °C
-
Weight: 1200 g