Technical data
 
Differential Pressure - Piezoresistive
 
  1. ±0.03 hPa (0 to 0.30 hPa)
  2.  ±0.05 hPa (0.31 to 1.00 hPa)
  3.  ±(0.1 hPa + 1.5 % of mv) (1.01 to 100 hPa)
 
General technical data
 
  1. Protection class IP40
  2. Seceltable units hPa, mbar, Pa, mmH2O, inHâ‚‚O, inHg, mmHg, psi, m/s, fpm
  3. Maximal static pressure 1.5 bar
  4. Measuring rate 0.5 s
  5. Battery type 2 AAA micro batteries
  6. Battery life 50 h (average, without display illumination)
  7. Dimensions 119 x 46 x 25 mm
  8. Operating temperature 0 to +50 °C
  9. Storage temperature -40 to +70 °C
  10. Weight 90 g (with batteries and protective cap)